Nnac and dc current probes pdf files

Model k2 has a greater level of sensitivity with its 10 mvma output. To do this, open the custom probes window, highlight the newly created probe, and then. Based on a combination of hall effect and transformer technology, teledyne lecroy current probes are ideal for making accurate ac, dc, and impulse current measurements. The five nac pilot states have implemented the tool in significantly differently ways, and have realized different levels of success. Ac current probes p6021 p6022 data sheet p6021 andp6022 ac currentprobes. Model k1 gives a 1 mvma output and lends itself to a variety of different applications, biased towards low current measurement.

The first probe is duplicated and edited to use a lookup table instead of an equation. The flexible probe allows current measurements on conductors that are hard to reach. Bestinclass current clamp sensitivity down to 1 ma. N7026a 150 mhz acdc high sensitivity current probes. P6021 and p6022 current probes the p6021 and p6022 current probes pro vide versatile ac current measurements. Dranetz ac flexible current probe, 1a to 10a 2tb94tr. Many of these current probes connect directly into the px54400 and encore series 6 instruments. Ac dc current probes k series k series the k series is a new product range with exceptional measurement capabilities. Flexible probes these type of probes are available in three lengths 60 cm, 90 cm and 120 cm lengths which allow monitoring currents up to 6000 amps full scale. To avoid personal injury, do not perform any servicing unless you are quali. Current clamps offer a safe, costeffective, simple and accurate way to take current measurements. The compact probes offer wide bandwidth with overcurrent protection. The current probe have a high bandwidth up to 2 mhz.

The probes utilize a combination of halleffect and transformer technology which enables measurements to be made on dc, ac and impulse currents. Current probes, sensors noncontact voltage probe,can. A single loop of wire passes through the center of the toroid core, inducing current in the secondary. The cp030, cp030a, cp031, and cp031a current probes are designed for easy, highly accurate current measurements. Tcp20215 ampere acdc current probe instruction manual.

The compact probes offer wide bandwidth with over current protection. The labdevice current probes are an affordable solution for ac and dc current profile measurements. N2820a21a highsensitivity, high dynamic range current. The current probe is designed for use with electromagnetic interference emi test receivers or spectrum analyzers, or with any similar instrument having a 50ohm input impedance. No part of this manual may be reproduced in any form or by any means including elec tronic storage and retrieval or translation into a foreign language without. To highlight the differences we will create another probe. N2780a series acdc current probes a wide selection of current probes to meet your applications needs data sheet various bandwidths. Inputs shielded probe heads ac only split core applications motor drives inverters power supply avionics p6021andp6022currentprobes.

Mn255 the mn255 is a high sensitivity probe with voltage outputs 100mva and 10mva and combine two switchselectable ranges of 20a and 200a, permitting accurate measurements at low and high levels. N2820a 3 mhz50ua high sensitivity acdc current probe 2. Looking for dranetz ac flexible current probe, 1a to 10a 2tb94. The electronics and batteries are selfcontained in the handles. These probes use a hybrid technology that includes a hall effect sensor which senses the dc current and a current transformer which senses the ac current. You could always improve it using better op amp and a. Precision current clamp suitable for nonintrusive current measurements in electrical electronic, process and light industrial systems automotive systems, battery performance testing and battery charging systems. Making measurements with the ac current probe models mn210mn211 connect the black lead of the current probe to common and the red lead to the ac current input on your dmm or other current measuring instrument. Tcp300400 series acdc current probes zzz instruction manual xx revision a this document applies for.

The tcp0020 and tcp2020 provide a maximum 20 a rms measurement range, while the tcp202a. This acdc current measurement probe provides greater than 120 mhz of bandwidth with selectable 5 a and 30 a measurement. Agilents ultra sensitive n2820an2821a current probes with resolution as low as 50 a excel at measuring for small current levels typically found in battery powered devices. Oscilloscope current probes low cost, high performance ac. The broadest range of acdc and aconly current probes.

They indicate the shape and amplitude of the current measured in the form of a voltage. Prova 6801 current probes 100a for prova 6830a current. It is designed to meet the needs of highspeed circuit design. Unlike current probes based on hall effect sensors, avcpseries current probes do not need to be demagnetized degaussed and can be used more easily over long periods of time. The flexible measuring head allows current measurements on. The ultrasensitive n2820a acdc current probe can support measurements from 50 ua to 5 a on keysights 3000 x, 4000 x, 9000, 9000 hseries oscilloscopes. Click the share button in the upperright corner when a pdf document is open in acrobat dc or acrobat reader dc. Bell y81gg dcac current probe is a clampon probe that is used with a voltmeter, multi meter, or oscilloscope to read dc, ac, or composite ac on dc current measurements. Dc to 2 mhz, 10 mhz, 50 mhz, 100 mhz dc and ac measurements superior 1% accuracy and high signaltonoise ratio overloadprotect function prevents probe damage from excessive input. There are two different types of k series current probes available. Ac current probe instruction sheet introduction the i6000s 24 flex and i6000s 36 flex ac current probes hereafter referred to as the probes are used with oscilloscopes, digital multimeters, recorders or data loggers. The sharing options are displayed in the right pane. Inputs shielded probe heads ac only split core p6022 935hzto120mhz 6apeak for 1 m. The clamp works perfect but is not the most professional tool ever, it is more as an example in order to understand the theory.

Ac current 200a dc current 200a accurate dc ac current probe 10madc, 1maac high resolution. Our range of current clamps can be used with picoscope oscilloscopes and picolog data loggers, as well all major brands of oscilloscopes and multimeters. N2820a 3 mhz50ua high sensitivity acdc current probe 2ch. The jaws on the y81gg are designed to clamp around conductors up to 34 inch in diameter. The mr series probes use hall effect technology and measure ac and dc current. The only products with 3rd party safety certification ul, csa, etl the only products with bare wire voltage ratings.

Ac current probes ct1 ct2 ct6 ct6 current probe the ct6 is the newest addition to the tektronix portfolio of highfrequency current probes. The model mr46 1 has two ranges and an autozero push button patent pending for quick dc zeroing. It is important to understand that the dcflex does not provide a continuous measurement of dc current. The broadest range of ac dc and aconly current probes. Making measurements with the ac current probe model jm875. Using split core construction, the current probes easily clip on and off a conductor, making it unnecessary to make an electrical connection to the circuit. Presentlythistypeofprobeisonlyavailablefromkeysight technologiesthen2820aandn2821acurrentprobes. The p6021 and p6022 allow current mea surements without breaking the circuit by clipping onto the current carrying conductor. Clampon clampon type probes are available to measure as low as 0. The dcflex is an easy to use, low cost, thin and cliparound dc current probe. Industrys highest sensitivity, highest dynamic range acdc current probes as modern batterypowered devices and integrated circuits become more. Their small dimensions and shape make them ideal for.

Lecroy current probes do not require the breaking of a circuit. Tcp202a 50 mhz, 15 a acdc current probe instruction manual. The hioki ct6845 is a 500 a acdc highprecision current probe for measuring power characteristics with high performance power meters and oscilloscopes. Labdevice provides measurements solutions for your electronics lab. The unit has proportional mv output for direct readings on handheld and bench top oscilloscopes. Ac current clamp model mini 01 with operating manual. Thank you for purchasing the current probe model mr417 or mr527. Based on a combination of hall effect and transformer technology, teledyne lecroy current probes are ideal for making accurate ac. Warning the servicing instructions are for use by quali.

Those that have achieved superior outcomes provide a set of best practices that should be considered as use of the nac continues in the current states and as expansion beyond the pilot is explored. Acdc currentprobes tcp0020 tcp2020 tcp202a ordering information tcp0020 acdc current probe. Clampon type probes are available to measure as low as 0. Extremely compact in design, these microprobes are designed for highly accurate measurement of very low currents.

The intelligent interface makes the probe ideal for use with the infiniivision and infiniium products using the autoprobe interface. Measurements from the low microamp ua up to the high milliamp ma range are possible. Also, there are available clampon probes that measure both ac and dc currents. The probe features low noise and low circuit insertion loss. Current probes, dc current probe, tektronix current probes, acdc music cds. The mn255 is a high sensitivity probe with voltage outputs 100mva and 10mva and combine two switchselectable ranges of 20a and 200a, permitting accurate measurements at low and high levels.

They are built to the latest safety and performance standards, including the ce mark. This acdc current measurement probe provides greater than 120 mhz of bandwidth with selectable 5 a and 30 a measurement ranges. This instrument is compliant with the iec 610102032 safety standard for voltages. The probes can be used to measure ac current up to 6000 a. You are covered by the ebay money back guarantee if you receive an item that is not as described in the listing.

To make an oscilloscope measurement, you must first be able to physically get the. The probes provide a 3 v full scale ac output proportional to the current being measured with three selectable ranges. Ac current 200a dc current 200a accurate dcac current probe 10madc, 1maac high resolution one touch zero for dca adjustment. Teledyne lecroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. A lineup of noncontact voltage probes and noncontact can sensors that sense voltage waveforms without contact. Both probes provide accurate current mea surements over awide range of frequencies. Differential current measurements single shot low reprate pulse measurements propagation delay measurement ac current probes ct1 ct2 ct6 ct6 current probe the ct6 is the newest addition to the tektronix portfolio of highfrequency current probes. Hioki current probes and sensors deliver broadband, highaccuracy performance from current probes for oscilloscopes to current sensors for power meters. The etslindgren current probe is a clampon rf current transformer that determines the intensity of rf current present in an electrical conductor or group of conductors. The mr521 is a general purpose 1500a ac or dc current probe designed for use with astronova recorders and data acquisition systems.

It is suitable for measuring large dc currents of 2ka. Alternatively, choose tools share, and then browse and select the pdf. The measurement principle is based on the hall effect that registers the magnetic field generated by the current flow. N2820a21a highsensitivity, high dynamic range current probes. Avcp current probes can be connected by bnc cable to nearly any commercial oscilloscope or dmm and are ideal for. Hioki acdc clamp sensors are bestinclass current sensors for use with power meters, memory hicorders and high performance oscilloscopes. N2780a series acdc current probes a wide selection of. The ct6846 is a highprecision a acdc current probe that features a wide operating temperature range and large jaw diameter, making them ideal for evaluating the operational integrity of devices that are subject to extreme temperature ranges. For the encore series 6 a 61mac input module allows connection of the available current probes to the instrument. The dcflex takes a single shot measurement of the dc current with a typical accuracy of 1%. Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one 1 year from the date of shipment. In the invite people section, enter, or choose the email address of. Evaluatingoscilloscopecurrentprobesforlowpowermeasurements.

Tcp0030a is a highperformance, easytouse acdc current probe designed for use and direct connection to oscilloscopes with the tekvpi probe interface. For best results from your instrument and for your safety, read the following operating instructions carefully and comply with the precautions for use. Acdc current probes for oscilloscopes and digital multimeters. Operation please make sure that you have already read and fully understand the warning section on page 1.

394 1313 546 1519 908 282 991 716 616 471 441 144 1261 588 233 790 1106 860 40 696 1309 467 1129 597 109 377 859 570 1390 1354 161 1114